DFX-8
Flaw Detector: Features


  • TRIG: Trigonometric display of beam path, depth, surface distance, and curved surface correction. Used with angle beam transducers.
  • DAC: Up to 16 points may be entered and used to digitally draw a DAC curve. Reference -2, -6, -10, (-6/-12), (-6/-14), (-2/-6/-10) dB. Amplitude displayed in %DAC or dB.
  • AWS: Automatic defect sizing in accordance with AWS D1.1 structural welding code.
  • AVG/DGS: Automatic defect sizing using probe data. Stores up to 64 custom setups.
  • TCG: Time corrected gain. 50 dB dynamic range, 20 dB per microsecond, up to 16 points for curve definition.
  • Measurement Mode: Pulse-Echo (P-E) measures from 0.025 in to 100 ft. (0.63mm to 3048 cm).
  • Auto-Cal: Provides automatic calibration with two reference points.
  • Detection Modes: Zero Crossing, Flank and Peak.
  • Display Freeze: Hold current waveform on screen.
  • Peak Memory: For echo dynamic pattern determination.


Thickness Gauge: Features


  • Measurement Modes (Dual Element):
  • Pulse-Echo Mode (P-E) – (Pit & Flaw Detection) measures from 0.025 in to 100 ft. (0.63mm to 3048 cm).
  • Pulse-Echo Coating Mode – (Material, Coating, Pit & Flaw Detection): Material: 0.025 in to 100 ft. (0.63mm to 3048 cm). Coating: 0.001 to 0.100 inches (0.01 to 2.54 millimeters).
  • Pulse-Echo Temp Comp Mode (PETP) – (Pit & FlawDetection) Auto temperature compensation – measures from 0.025 in to 100 ft. (0.63 mm to 3048 cm).
  • Echo-Echo Mode (E-E) – (Thru Paint & Coatings) measures from 0.050 to 4.0 inches (1.27 to 102 millimeters). Will vary based on coating.
  • Echo-Echo Verify (E-EV) – (Thru Paint & Coatings) measures from 0.050 to 1.0 inches (1.27 to 25.4 millimeters). Will vary based on coating.
  • Coating Only Mode (CT) – (Coating Thickness) Measures from 0.0005 to 0.100 inches (0.0127 to 2.54 millimeters). Range will vary +/- depending on the coating.
  • One and two point calibration option for material and coating, or selection of basic material types.
  • Auto probe zero, recognition and temperature compensation.
  • High speed scan up to 50 readings per second.
  • Audible alarm with hi/lo limits.
  • Built-in differential mode for QC inspections.
  • 64 custom setup configurations.


DFX-8 Specifications