Xpress Scan GW


DIGITAL RADIOGRAPHY SYSTEM PROVIDES:

  • lower inspection costs by eliminating consumables (X-ray film and film processing chemicals), film processing equipment, film storage facilities
  • inspection results obtained online make it possible to correct welding settings immediately to avoid more defects
  • perfect conditions for image examination (zoom, optimal contrast, image enhancement procedures) and inspection protocol preparation
  • easy use of database

SYSTEM SPECIFICATIONS:

 

Detector

  • a-Si detector
  • Resolution: 4lp/mm (127µmpixelsize)
  • Image size: 145×145mm
  • X-ray energy: up to 300 keV
  • Operating temperature: –40° to +30°

 

Software

  • Real-time X-ray image acquisition
  • Exposure control and image processing and archival using DiSoft software
  • The digital image is stored as a file of a fully documented DICONDE format compliant to  ASTM  E2339–11 standard, which ensures the readability of all information, including metadata, using software by different vendors

 

Data Transfer and Power Supply

  • Data transfer to the operator's laptop  with Wi-Fi, up to 300 m
  • Data    storage: internal memory of the detector; in case of Wi-Fi connection failure, the exposure continues, and the data is secured
  • Detector power supply: Li-Ion battery (battery life 2 hours, min. charge time 15 min)

 

Dimensions and Weight

  • Detector with battery  and data transfer system: 19×19×12cm, 4kg

 

Accessories

  • Battery pack charger, 12/24/220 V input voltage.
  • Wire or step/hole IQIs


Xpress Scan2017 Flyer